Note: The Fisher EIE has been updated and its functionality has been split by native protocol between the Emerson ROC EIE and the Emerson ROCPlus EIE. If you currently have Fisher EIEs deployed, refer to Fisher EIE documentation released in earlier versions of the CygNet Help. If you are installing Fisher or Emerson field devices and want to use EIEs to support their use with CygNet and/or you have upgraded to Emerson ROC EIEs or Emerson ROCPlus EIEs, refer to Emerson ROC EIE and Emerson ROCPlus EIE documentation.
The Emerson ROC EIE supports interoperation with several common Emerson Process Management field devices, including ROC, FloBoss, and RegFlo devices.
Native data groups available for this EIE reflect TLP (point type, location/logic, parameter) groupings offered by Emerson ROC field devices. In such cases, opcodes and TLPs are hard-coded into the CygNet data group. This streamlines access to common Emerson ROC TLP groupings, enabling read/write messaging to occur with a minimum of setup.
In addition to native, predefined data groups, CygNet provides a special data group type called a "Generic TLP Data" data group. You can add as many instances of this data group type as necessary to form your own collections of up to 30 TLPs per "Generic TLP Data" data group. Some might be TLPs already part of a native data group and some might not be predefined by CygNet at all. Effectively, you can use the "Generic TLP Data" data group type to access any TLP on any supported Emerson ROC model and to group and use them according to your needs.
Although the Emerson ROC EIE depends on various model-specific device template files, Emerson ROC device template files are relatively inflexible. Each was written to interface with a proprietary (ROC) protocol and so they must meet Emerson ROC specifications very closely.
CygNet supports Emerson field devices that use either the ROC protocol or ROCPlus protocol, depending on model number. For information about Emerson ROCPlus devices, see Emerson ROCPlus EIE.
For more specific information about Emerson Process Management field devices, see the appropriate manufacturer-provided documentation.
Note: A valid "ROC Config" (RtuConfig) data group must be retrieved before other data groups can be retrieved or sent. The data group should always be repolled if there are configuration changes to the field device, after a CygNet upgrade, after importing a device or after modifying the device template file.
The following table lists and describes EIE specifications.
| Manufacturer | Emerson Process Management |
|
Protocol(s) |
ROC protocol (non-ROC800-Series devices) |
|
Model(s) |
FloBoss 100 FloBoss 107 FloBoss 107IC FloBoss 400 FloBoss 400IC FloBoss 500 ROC300 ROC300IC FBx (1100; 1200; 2100; 2200) RegFlo |
|
Required Files |
CxDdsEmersonRocEditors.dll UisEmersonRocDriver.dll |
|
FMS Import File |
The following file is required for importing data from an Emerson export file into FMS:
For more information, see Installing CygNet Measurement and Import: EmersonROC Laptop File in the CygNet Measurement section. |
|
Sample Templates |
EmersonRoc100.dtf EmersonRoc107.dtf EmersonRoc107IC.dtf (Industry Canada) EmersonRoc300.dtf EmersonRoc300IC.dtf (Industry Canada) EmersonRoc400.dtf EmersonRoc400IC.dtf (Industry Canada) EmersonRoc500.dtf EmersonRoc_FBx.dtf |
|
Cryout Support |
Yes |
|
FMS Support |
Yes, using FMS EFM data items |
|
Note: In cases where both GMR and FMS support was previously available, CygNet Measurement now provides data support using FMS data items only. If you were previously using GMR data items, you must update to use FMS data items. Update options are provided as part of your software upgrade procedure. See the CygNet Upgrade Procedure for more information. |
|
|
Listen Mode |
Yes |
|
64-bit Support |
Yes. See 64-bit Device Drivers. |
For more information, see sample device template files and manufacturer documentation.